442
| BI | Basically intact |
A few non-main parts of the building structure were slightly damaged, individual doors or window openings, wall corners, brick arches and extruding parts of the building had occasional small cracks on otherwise intact buildings.
|
443
| SLD | Slightly damaged |
Non-main part of the building structure obviously damaged; small cracks and constructional cracks occurred on a few walls and panels, obvious cracks occasionally occurred on individual walls but most of the walls were not damaged.
|
444
| MD | Moderately damaged |
Apparent cracks occurred on the main part of the building structure or at several connections; filled walls and attached buildings were seriously damaged or even collapsed.
|
445
| SD | Seriously damaged |
The main part of the building structure seriously damaged; walls cracked and shifted, were offset or loosened, parts of the corner fell down, part of the exterior wall fell or individual walls or panels collapsed.
|
446
| C | Collapsed |
All exterior walls nearly collapsed, or the top story of buildings with a timber roof mostly collapsed, or the load-bearing structure partly collapsed.
|
447
| CC | Completely collapsed |
Whole buildings collapsed and fell to the ground, or several upper stories of the building collapsed, or most of the building collapsed with a small part remaining.
|